Mercedes-Benz W210 Engine fan warning and cooling fan not running

E200 CDIE220 CDIE270 CDI

What causes the W210 Engine fan - Visit workshop warning?

Causes have included a blown 7.5 A engine management fuse, a faulty intake air temperature sensor, seized fan bearings or a faulty control unit. Read the fault codes first before replacing parts.

Where is the fan control unit and what happens if the control is missing?

The control unit is at the front on the driver's side, inside the bumper above the fog light. If the fan does not receive a control signal, it runs at full speed. The fan itself should not prevent driving.

How do I find out whether the fault is in the fan or in the control?

If the fan runs when you give it 12 V directly, the motor is fine and the fault is in the control: the control unit, its wiring or the fuse. If it does not run, the fan bearings may be dry or seized.